Specification:


ModelFA-XIS-2080D
X-ray Tube Single tube Max. 120KV, 480W
Inspection Width180mm
Inspectin Height250mm
Best Inspection SensitivitySUS Ball Dia 0.4mm SUS Wire Dia 0.3*2mm
Conveyor Speed10-70m/min
Operation Environment

Temprature: -10-40℃

Cooling Method: Industrial Air Conditioner

Humidity:30-90%, Forsting-free humidity

Control:Dehumidifier

X-ray Leakage<1 microsievert per hour
RejectorPusher Type
Pressure Requirement0.6-0.8Mpa
Power SupplyAC220V, 1.5KVA Max, 50/60HZ
IP RatingIP66
Main Material
SUS304


 Note:


The technical parameter above namely is the result of sensitivity by inspecting only the test sample on the belt. The actual sensitivity would be affected according to the products being inspected.


     Dual-beam X-ray Inspection System


Video Clipshttps://www.youtube.com/watch?v=bez4tDtCpNE

Suitable for standing products such as upright cans, bottles and boxes etc.

Features: 

1. Applying double sets of imaging systems, to achieve inspection in double visual angles and avoid missing inspection of blind area


2. Intelligent zoning to ensure optimal sensitivity for different areas


3. Multi-functional, to achieve the inspection for foreign bodies, caps filling level and packing defects synchronously



Specification:


ModelFA-XIS-2080D
X-ray Tube Single tube Max. 120KV, 480W
Inspection Width180mm
Inspectin Height250mm
Best Inspection SensitivitySUS Ball Dia 0.4mm SUS Wire Dia 0.3*2mm
Conveyor Speed10-70m/min
Operation Environment

Temprature: -10-40℃

Cooling Method: Industrial Air Conditioner

Humidity:30-90%, Forsting-free humidity

Control:Dehumidifier

X-ray Leakage<1 microsievert per hour
RejectorPusher Type
Pressure Requirement0.6-0.8Mpa
Power SupplyAC220V, 1.5KVA Max, 50/60HZ
IP RatingIP66
Main Material
SUS304